Affordable, fast and accurate! Ask Bing -- The Building Code Consultant and Mentor with experience of code enforcement (12 years in the City of Calgary as Plans Examiner and Safety Codes Officer Engineer, 1 year in the City of Saskatoon as Senior Building Code Engineer, reviewed and approved more than 8000 projects), aims to help building designers and owners saving TIME and MONEY.
▼
Friday, March 6, 2020
Articles need to know!!! hashtag#interconnectedfloorspace
Articles need to know!!! interconnectedfloorspace
3.2.8.2. Exceptions to Special Protection
6) An interconnected floor space need not conform to the requirements of Article 3.2.8.3. to 3.2.8.8., provided
a) it consists of the first storey and the storey next above or below it, but not both,
b) it is sprinklered throughout or, where the building area is not more than one half of the area permitted by Subsection 3.2.2., the openings through the floor are used only for stairways, escalators or moving walks, and
c) It contains only Group A, Division 1, 2 or 3, Group D, Group E, or Group F, Division 2 or 3 major occupancies.
There is an important change in this article from the old code. That is: the interconnected floor space is permitted without special protection as long as the building is sprinlered.