Thursday, September 28, 2023

9.10.16.2. Required Fire Blocks in Wall Assemblies

 9.10.16.2. Required Fire Blocks in #Wall Assemblies


#Furring or #strapping can also create spaces that allow fire spread. These should also be blocked off at each #floor level and at the #ceiling level if the ceiling #membrane provides part of the required fire resistance (Figure 9.10.-38). Since furring can be installed either horizontally or vertically, both the horizontal and vertical spacings of fire blocks are limited (20 m (65 ft. 7 in.) and 3 m (10 ft.), respectively).

Quoted for Illustrated Users' Guide - NBC2015
#fireblock #fireresistance



No comments:

Post a Comment