Friday, June 10, 2022

Location of Firewall


Can we put firewalls on any location we like to build one huge building?
There are 3 firewalls on the floor plan below. What are the implications of these firewalls in our design?
#design #building #firewalls


Firewall vs Fire Separation


On the following two floor plans, one has a 1h fire separation and the other has a 2h firewall at the same location.
What shall we consider differently in designing? Please give your list of differences by comments.
#firewalls #fireseparation

Saturday, June 4, 2022

Tell the Difference

2015 National Building Code

9.10.4.4. Roof-Top Enclosures


1) Roof-top enclosures provided for elevator machinery, stairways or service rooms, used for no purpose other than for service to the building, shall not be considered as a storey in calculating the building height.


2018 BC Building Code

9.10.4.4. Roof-Top Enclosures


1) A roof-top enclosure shall not be considered as a storey in calculating the building height if the roof-top enclosure is provided for

a) elevator machinery,

b) a service room,

c) a stairway used for no purpose other than for access or egress,

d) an elevator lobby used for no purpose other than for access or egress, or

e) a combination thereof


The difference is:

If you are designing a 3 storey townhouse with a roof top patio and stairway, it will be 3 storey in BC, but 4 storey in other provinces, such as Alberta and Saskatchewan.

Existing Buildings Do Not Automatically Have to Meet Today’s Building Code

  Existing Buildings Do Not Automatically Have to Meet Today’s Building Code One of the most expensive assumptions in a renovation project i...