Tuesday, November 24, 2020

Quiz

 Quiz


1. Load bearing elements supporting a service room must have the same fire-resistance rating as that required for the service room.

a) true

b) false


2. Interior fire separations shall be rated for fire exposure to fire from one side only

a) true

b) false


3. A fire compartment must always be enclosed on all sides by fire separation with a required fire-resistance rating.

a) true

b) false


4. Fire separations cannot have any penetrations into or through them.
a) true
b) false


Quiz:


5. Fire separations must be continuous through horizontal service spaces.

a) true

b) false


Quiz


6. Secondary suites are not permitted in an existing row house?

a) true

b) false


7. A closure to be installed in a 1 h fire separation needs a fire-protection rating of:

a) 1h

b) 20 min

c) 30 min

d) 45min


8. Twenty-minute closures are permitted between all public corridors and adjacent suites.

a) true

b) false


9. In order to be continuous, fire separations must have protected openings.

a) true

b) false


10. The maximum area of a closure in a fire separation in an unsprinkelered building is:

a) 3.7 sqm

b) 10 sqm

c) 11 sqm

d) 22 sqm


11. Openable wired glass window assemblies can be used as closures in fire separations with a fire-resistance rating of not more than one hour.

a) true

b) false



12. Wired glass assemblies that are not tested and are used in a vertical fire separation shall have a glass thickness of at least:

a) 0.6 mm

b) 6 mm

c) 10 mm

d) 16 mm



13. The minimum concrete cover to a totally enclosed combustible raceway embedded in the assembly in a concrete floor shall be not less than:

a) 25 mm

b) 50 mm

c) 60 mm

d)100 mm



14. Combustible drain piping is not permitted to penetrate horizontal fire separations under any circumstances.

a) true

b) false


15. Combustible sprinkler piping is permitted to penetrate fire separations.

a) true

b) false


16. One of the major reasons for the use of firewalls is:
a) to divide a building into equal segments.
b) to allow for less restrictive construction requirements.
c) to allow for less restrictive fire safety.
d) to express a visual boundary between two parts of a building.


17. Two noncombustible materials used to construct firewalls are:

a) masonry and concrete

b) natural stone and concrete

c) masonry and natural stone

d) steel and gypsum board


18. Restrictions on openings through firewalls are limited to size only.


a) true

b) false



19. All firewalls must extend through the roof to form a parapet.


a) true

b) false


20. A parapet forming part of a four-hour firewall must extend above the roof:


a) 100 mm

b) 150 mm

c) 400 mm

d) 900 mm


21. The minimum fire-resistance rating for a firewall is:


a) 45 min

b) 1 h

c) 1.5 h

d) 2 h


22. The required fire-resistance rating of a firewall that separates a building with floor areas containing Group D and Group C occupancies is:


a) 45 min

b) 1 h

c) 2 h

d) 4 h


23. When Buildings are separated by a firewall, combustible projections on the exterior of one building that extend outward shall not be permitted closer to combustible projections of the adjacent building than:


a) 2m

b) 2.4m

c) 3.4m

d) 10m



24. It is proposed to allow a combustible eave projection on both sides of a firewall that terminates flush with the exterior wall to come up to the edges of the vertical exposed face of the firewall. Does this comply the National Building Code?


a) yes

b) no



25. The minimum fire-resistance rating for a floor assembly immediately above a basement is:


a) 90 min

b) 60 min

c) 45 min

d) 20 min


26. What is the maximum size of fire compartments in a basement that is required to be subdivided?


a) 200 sqm

b) 400 sqm

c) 600 sqm

d) 800 sqm


27. The minimum fire-resistance rating for loadbearing elements supporting a floor assembly immediately above a basement is:


a) 60 min

b) 90 min

c) 20 min

d) non of the above



28. The term "fire suppression system" includes:


a) CO2 systems

b) sprinkler systems

c) dry chemical systems

d) wet chemical systems

e) all of the above



29. A small foreman's office in a large manufacturing plant is considered a major occupancy and therefore the building is subject to the NBC's multiple occupancy requirements.


a) true

b) false



30. In the case of a building containing multiple major occupancies located one above the other, the entire building area and building height must be taken into consideration to determine fire safety requirements.


a) true

b) false


31. A basement used primarily as a storage garage must be considered as a separate building.


a) true

b) false


32. A floor assembly immediately above a crawl space is not required to be constructed as a fire separation and is not required to have a fire-resistance rating.


a) true

b) false


33. A building required to be of noncombustible construction has a crawl space that is used as a return air plenum. Must this crawl space be considered as a basement?


a) yes

b) no



34. By definition, a street can't be narrower than:


a) 19m

b) 9m

c) 8m

d) 7m


35. A street, as defined, must be:


a) paved with asphalt

b) deeded for public use

c) accessible to fire department vehicles and equipment

d) at least 8m wide

e) both (b) and (c)


36. Every building shall face at least two streets.

a) yes

b) no



37. For a building to face two streets, not less than the following percentage of the building's perimeter must be within 15m of the streets:


a) 15

b) 20

c) 40

d) 50


38. The fire resistance rating requirements for roofs in sprinklered buildings are waived even if these roofs are occasionally used for purpose other than for servicing or maintenance.


a) true

b) false


39. The limiting distance from an exposing building face to a street is measured to the nearest street boundary.

a) true

b) false


40. The height of an exposing building face is measured between the top of the first storey floor and the top of the roof


a) true

b) false


41. A building classified as a Group E major occupancy has one of its exterior walls facing a property line at a distance that permits 20% unprotected openings. The fire-resistance rating for the wall must be at least:


a) 45min

b) 1.5h

c) 2h

d) 3h






Sunday, October 25, 2020

3.1.13.6. Corridors

 Articles need to know!!!


3.1.13.6. Corridors


1) Except as permitted by Sentence (2) and (3), the flame-spread rating shall be not more than 75 for the interior wall finish of

a) a public corridor,

b) a corridor used by the public in an assembly occupancy, or

c) a corridor serving classrooms.


2) The flame-spread rating for corridors specified in Sentence (1) is permitted to be waived, provided the flame-spread rating is not more than

a) 25 on the upper half of the wall, and

b) 150 on the lower half of the wall


3) Where the floor area is sprinklered, the flame-spread ratings for corridors specified in Sentence (1) and (2) shall be not more than 150


4) the flame-spread ratings specified in Sentence (1), (2) and (3) apply to occupancies in the corridor as well as to the corridor itself.


5) except as provided in Sentence (6), the interior ceiling finish of corridors and occupancies referred in Sentence (1) and (4) shall have a flame-spread rating not more than 25.


6) Where the floor area is sprinkelered throughout, the flame-spread rating of the interior ceiling finish of corridors and occupancies referred in Sentence (1) and (4) shall be not more than 150.


Question:

When are decorative wood finishes permitted in a public corridor?


Please have your answer by comments.

Thursday, October 15, 2020

3.1.13.5. Skylights

 Articles need to know!!!


3.1.13.5. Skylights

1) Individual combustible skylights in a corridor that is required to be separated from the remainder of the building by a fire separation shall be not more than 1 sqm in area and not less than 1.2 m apart.


Question:

What is the minimum distance between skylights in a public corridor?


Please have your answer by comments.

Tuesday, September 29, 2020

3.1.10.7. Combustible Projections

 Articles need to know!!!


3.1.10.7. Combustible Projections


1) Combustible material shall not extend across the end of a firewall but is permitted to extend across a roof above a firewall that is terminated in conformance with the Sentence 3.1.10.3.(2).


2) If buildings are separated by a firewall, combustible projections on the exterior of one building, including balconies, platforms, canopies, eave projections and stairs, That extend outward beyond the end of the firewall, shall not be permitted within 2.4m of combustible projections and window or door openings of the adjacent buildings.


Question:

When is combustible material permitted to extend across a roof above a firewall?

Friday, September 25, 2020

3.1.10.4 Parapets

 3.1.10.4 Parapets


1) Except as permitted by Sentences (2) and 3.1.10.3.(2), a firewall shall extend above the roof surface to form a parapet not less than

a) 150 mm high for a firewall required to have a fire-resistance rating not less than 2h

b) 900 mm high for a firewall required to have a fire-resistance rating not less than 4h


2) A firewall that separates 2 buildings with roofs at different elevations need not extend above the upper roof surface to form a parapet, provided the difference in elevation between the roofs is more than 3m.


Question:

What will you be looking for to determine if a building is separated by a firewall?


Please leave your answer by comments.

Wednesday, September 16, 2020

3.1.9.6. Openings through a Membrane Ceiling

 Articles need to know!!!


3.1.9.6. Openings through a Membrane Ceiling


1) A membrane ceiling forming part of an assembly assigned a fire-resistance rating on the basis of Appendix D is permitted to be penetrated by openings leading into ducts within the ceiling space, provided

a) the ducts are sheet steel, and

b) the number of openings and their protection conform to the requirements of Appendix D


Question:

Are recessed lighting fixtures are permitted to penetrate the membrane ceiling with fire resistance rating?


Please leave your answer by comments.

Wednesday, September 9, 2020

3.2.3.19. Walkway between Buildings

 Articles need to know!!!


3.2.3.19. Walkway between Buildings


1) Except as required by Sentence 3.2.3.20.(2), if buildings are connected by a walkway, each building shall be separated from the walkway by a fire separation with a fire resistance rating not less than 45min.


Question: Is walkway a public corridor?


Please have your answer by comments.

Thursday, September 3, 2020

3.4.4.4. Integrity of Exits

 Articles need to know!!!


3.4.4.4. Integrity of Exits

6) An exit shall be designed for no purpose other than for exiting, except that an exit is permitted also to be designed to serve as an access to a floor area.


Question:

Does an entrance to a building have to be an exit?


Please leave your answer by comments.