Code Discussion: Micro-Distillery
A micro distillery owner wants to have a 70 people tasting bar in a F2 building.
What are the key code items to be considered?
How do you resolve the code issues?
Is it possible?
Affordable, fast and accurate! Ask Bing -- The Building Code Consultant and Mentor with experience of code enforcement (12 years in the City of Calgary as Plans Examiner and Safety Codes Officer Engineer, 1 year in the City of Saskatoon as Senior Building Code Engineer, reviewed and approved more than 8000 projects), aims to help building designers and owners saving TIME and MONEY.
Code Discussion: Micro-Distillery
A micro distillery owner wants to have a 70 people tasting bar in a F2 building.
What are the key code items to be considered?
How do you resolve the code issues?
Is it possible?
This article is important
3.2.3.13.2) If an unenclosed exterior exit stair or ramp could be exposed to fire from an opening in the exterior wall of the building it serves, the opening in the exterior wall of the building shall be protected in conformance with the requirements of Sentence (4) where the opening in the exterior wall of the building is within 3m horizontally and
a) less than 10m below the exit stair or ramp, or
b) less than 5m above the exit stair or ramp.
Discussion
What do you prefer if you don't understand a building code article?
a) asking another designer
b) asking my supervisor
c) asking a building code consultant
d) keeping it a secret
Articles need to know
3.1.8.14 Hold-Open Devices
1) Except as provided in Sentences 3.1.8.10.(2) and 3.1.8.11.(3), a hold-open device is permitted to be used on a closure in a required fire separation, other than on an exit stair door in a building more than 3 storeys in building height and on a door for a vestibule required by Article 3.3.5.7., provided the device is designed to release the closure in conformance with this Article.
3.1.8.13. Self- Closing Devices
1) Except as permitted by Sentence (2), every door in a fire separation, other than doors to freight elevators and dumbwaiters, shall be equipped with a self-closing device designed to return the door to the closed position after each use.
Key Definition--Fire Damper
Fire damper means a closure which consists of a damper installed in an air distribution system or in a wall or floor assembly, which is normally held open but is designed to close automatically in the event of a fire in order to maintain the integrity of the fire separation.
When Do You Need a Professional Plans Examiner?
You probably need a Professional Plans Examiner to help you when you are not sure:
1. The building classification
2. The spatial separation and exposure protection
3. The difference between a mezzanine and a second storey
4. The exits
5. The proper fire separations
6. The secondary suites
7. The accessibility or
8. Any items related to building code and fire code
Quiz
1. Load bearing elements supporting a service room must have the same fire-resistance rating as that required for the service room.
a) true
b) false
2. Interior fire separations shall be rated for fire exposure to fire from one side only
a) true
b) false
3. A fire compartment must always be enclosed on all sides by fire separation with a required fire-resistance rating.
a) true
b) false
4. Fire separations cannot have any penetrations into or through them.
a) true
b) false
Quiz:
5. Fire separations must be continuous through horizontal service spaces.
a) true
b) false
Quiz
6. Secondary suites are not permitted in an existing row house?
a) true
b) false
7. A closure to be installed in a 1 h fire separation needs a fire-protection rating of:
a) 1h
b) 20 min
c) 30 min
d) 45min
8. Twenty-minute closures are permitted between all public corridors and adjacent suites.
a) true
b) false
9. In order to be continuous, fire separations must have protected openings.
a) true
b) false
10. The maximum area of a closure in a fire separation in an unsprinkelered building is:
a) 3.7 sqm
b) 10 sqm
c) 11 sqm
d) 22 sqm
11. Openable wired glass window assemblies can be used as closures in fire separations with a fire-resistance rating of not more than one hour.
a) true
b) false
12. Wired glass assemblies that are not tested and are used in a vertical fire separation shall have a glass thickness of at least:
a) 0.6 mm
b) 6 mm
c) 10 mm
d) 16 mm
13. The minimum concrete cover to a totally enclosed combustible raceway embedded in the assembly in a concrete floor shall be not less than:
a) 25 mm
b) 50 mm
c) 60 mm
d)100 mm
14. Combustible drain piping is not permitted to penetrate horizontal fire separations under any circumstances.
a) true
b) false
15. Combustible sprinkler piping is permitted to penetrate fire separations.
a) true
b) false
16. One of the major reasons for the use of firewalls is:
a) to divide a building into equal segments.
b) to allow for less restrictive construction requirements.
c) to allow for less restrictive fire safety.
d) to express a visual boundary between two parts of a building.
17. Two noncombustible materials used to construct firewalls are:
a) masonry and concrete
b) natural stone and concrete
c) masonry and natural stone
d) steel and gypsum board
18. Restrictions on openings through firewalls are limited to size only.
a) true
b) false
19. All firewalls must extend through the roof to form a parapet.
a) true
b) false
20. A parapet forming part of a four-hour firewall must extend above the roof:
a) 100 mm
b) 150 mm
c) 400 mm
d) 900 mm
21. The minimum fire-resistance rating for a firewall is:
a) 45 min
b) 1 h
c) 1.5 h
d) 2 h
22. The required fire-resistance rating of a firewall that separates a building with floor areas containing Group D and Group C occupancies is:
a) 45 min
b) 1 h
c) 2 h
d) 4 h
23. When Buildings are separated by a firewall, combustible projections on the exterior of one building that extend outward shall not be permitted closer to combustible projections of the adjacent building than:
a) 2m
b) 2.4m
c) 3.4m
d) 10m
24. It is proposed to allow a combustible eave projection on both sides of a firewall that terminates flush with the exterior wall to come up to the edges of the vertical exposed face of the firewall. Does this comply the National Building Code?
a) yes
b) no
25. The minimum fire-resistance rating for a floor assembly immediately above a basement is:
a) 90 min
b) 60 min
c) 45 min
d) 20 min
26. What is the maximum size of fire compartments in a basement that is required to be subdivided?
a) 200 sqm
b) 400 sqm
c) 600 sqm
d) 800 sqm
27. The minimum fire-resistance rating for loadbearing elements supporting a floor assembly immediately above a basement is:
a) 60 min
b) 90 min
c) 20 min
d) non of the above
28. The term "fire suppression system" includes:
a) CO2 systems
b) sprinkler systems
c) dry chemical systems
d) wet chemical systems
e) all of the above
29. A small foreman's office in a large manufacturing plant is considered a major occupancy and therefore the building is subject to the NBC's multiple occupancy requirements.
a) true
b) false
30. In the case of a building containing multiple major occupancies located one above the other, the entire building area and building height must be taken into consideration to determine fire safety requirements.
a) true
b) false
31. A basement used primarily as a storage garage must be considered as a separate building.
a) true
b) false
32. A floor assembly immediately above a crawl space is not required to be constructed as a fire separation and is not required to have a fire-resistance rating.
a) true
b) false
33. A building required to be of noncombustible construction has a crawl space that is used as a return air plenum. Must this crawl space be considered as a basement?
a) yes
b) no
34. By definition, a street can't be narrower than:
a) 19m
b) 9m
c) 8m
d) 7m
35. A street, as defined, must be:
a) paved with asphalt
b) deeded for public use
c) accessible to fire department vehicles and equipment
d) at least 8m wide
e) both (b) and (c)
36. Every building shall face at least two streets.
a) yes
b) no
37. For a building to face two streets, not less than the following percentage of the building's perimeter must be within 15m of the streets:
a) 15
b) 20
c) 40
d) 50
38. The fire resistance rating requirements for roofs in sprinklered buildings are waived even if these roofs are occasionally used for purpose other than for servicing or maintenance.
a) true
b) false
39. The limiting distance from an exposing building face to a street is measured to the nearest street boundary.
a) true
b) false
40. The height of an exposing building face is measured between the top of the first storey floor and the top of the roof
a) true
b) false
41. A building classified as a Group E major occupancy has one of its exterior walls facing a property line at a distance that permits 20% unprotected openings. The fire-resistance rating for the wall must be at least:
a) 45min
b) 1.5h
c) 2h
d) 3h
Ramps A ramp located in a barrier-free path of travel shall have a level area not less than 1700 mm by 1700 mm at the #top and #bottom an...