3.1.3.2. Prohibition of Occupancy Combinations

3) A building conforming to Article 3.2.2.50. shall not contain
a) except as provided in Sentence (5), a Group A, Division 1 or 3, Group B, or Group F, Division 2 or 3 major occupancy, or
b) a Group A, Division 2 or Group E major occupancy above the second storey.

4) A building conforming to Article 3.2.2.2.58. shall not contain
a) a Group A, Division 1 or 3,  or Group B, or group F, Division 1 major occupancy, or
b) except as provided in Sentence (5), a Group A, Division 2, Group E, or Group F, Division 2 or 3 major occupancy above the second storey.

5) A building conforming to Article 3.2.2.50. or 3.2.2.58. is permitted to contain a storage garage below the forth storey.