Monday, July 8, 2024

9.10.19.3. Location of Smoke Alarms

 9.10.19.3. Location of Smoke Alarms


This Article indicates where smoke alarms are required in dwelling units. Since the prime purpose of a smoke alarm is to wake the sleeping #occupants in the #suite in which the fire originated, smoke alarms are installed in each #bedroom and in the #hallway that serves them. To avoid any delay in warning due to the time it takes for smoke to travel from storey to #storey, and to allow for the fact that other habitable #rooms can be used for sleeping, additional smoke detectors must be installed on other storeys, including #basements.

 A smoke alarm installed in the living area and wired to sound another smoke alarm located near bedrooms is the ideal solution (Figure 9.10.-40).
Quoted from Illustrated Users' Guide - NBC 2015
#smokealarm #dwellingunit #smokedetector