Affordable, fast and accurate! Ask Bing -- The Building Code Consultant and Mentor with experience of code enforcement (12 years in the City of Calgary as Plans Examiner and Safety Codes Officer Engineer, 1 year in the City of Saskatoon as Senior Building Code Engineer, reviewed and approved more than 8000 projects), aims to help building designers and owners saving TIME and MONEY.
Thursday, March 12, 2020
3.4.4.3. Exterior Passageway Exceptions
Articles need to know!!! Exitseparation
3.4.4.3. Exterior Passageway Exceptions
1) The requirements of Sentence 3.4.4.1.(1) (Fire resistance rating of Exit Separation) and 3.2.3.13. (1) and (3) (Protection of Exit Facilities) don't apply to an exterior exit passageway provided
a) not less than 50% of the exterior side is open to the outdoors, and
b) an exit stair is provided at each end of the passageway